7.4. Prepare Data
7.4.1. QGEP - SWMM correspondances
7.4.1.1. Title/Notes:
No correspondance in QGEP. This parameter must be set by the user in the template .inp
file or before running the simulation.
Copied from the template input file if exists.
7.4.1.2. Options:
No correspondance in QGEP. This parameter must be set by the user in the template .inp
file or before running the simulation.
Copied from the template input file if exists.
7.4.1.3. Climatology:
No correspondance in QGEP. This parameter must be set by the user in the template .inp
file or before running the simulation.
Copied from the template input file if exists.
7.4.1.4. Hydrology:
Rain Gauges [Gages in SWMM]:
QGEP_SWMM creates one raingage for each subcatchment.
By default:
Time serie: Each raingage is related to a default rain time serie called
default_qgep_raingage_timeserie
. The time serie must be created and the value Series Name updated accordingly.Format is set to “INTENSITY”. Format in which the rain data are supplied: INTENSITY: each rainfall value is an average rate in inches/hour (or mm/hour) over the recording interval. VOLUME: each rainfall value is the volume of rain that fell in the recording interval (in inches or millimeters). CUMULATIVE: each rainfall value represents the cumulative rainfall that has occurred since the start of the last series of non-zero values (in inches or millimeters).
Interval is set to “0:15” (15 seconds). Recording time interval between gage readings in decimal hours or hours:minutes format.
Other parameters have default SWMM values. If you want to use another Format or Interval, you have to adapt the view.
See vw_swmm_raingages.sql
for details.
Aquifers:
QGEP_SWMM creates an aquifer for each QGEP aquifiers
.
By default:
An aquifer is created for each QGEP
aquifiers
The bottom elevation is set to the
minimal_groundwater_level
The water table elevation is set to the
average_groundwater_level
Other parameters have default SWMM values
See vw_swmm_aquifers.sql
for details.
Subcatchment:
QGEP_SWMM creates a subcatchment for each QGEP catchment area.
By default:
A subcatchment is created for each QGEP
wastewater_networkelement
linked to thecatchment area
(max. 4:fk_wastewater_networkelement_rw_current
,fk_wastewater_networkelement_rw_planned
,fk_wastewater_networkelement_ww_current
,fk_wastewater_networkelement_ww_planned
)it is linked to a rain gage.
The width is computed from the mean of the minimal / maximal distance between the outlet and the catchment area contour. If the outlet is unknown the centroid is used rather than the outlet.
The coverages (attribute land uses) are computed from the intersection between the catchment area and the planning zone (see
vw_swmm_coverages.sql
)SWMM Dry Weather Flow:
are set to 0 for rain water subcatchments
are set to
waste_water_production[_current,_planned]
if setelse it computed from the subcatchement area and
population_density[_current,_planned]
Other parameters have default SWMM values
The subcatchment can be linked to an aquifer via the groundwater attribute.
See vw_swmm_subcatchments.sql
, vw_swmm_subareas.sql
, vw_swmm_dwf.sql
and vw_swmm_coverages.sql
for details.
Snow Packs
No correspondance in QGEP. This parameter must be set by the user in the template .inp
file or before running the simulation.
Copied from the template input file if exists.
Unit hydrographs
No correspondance in QGEP. This parameter must be set by the user in the template .inp
file or before running the simulation.
Copied from the template input file if exists.
LID Controls
No correspondance in QGEP. This parameter must be set by the user in the template .inp
file or before running the simulation.
Copied from the template input file if exists.
7.4.1.5. Hydraulics
Junctions
QGEP_SWMM creates a junction for each QGEP manhole, some kind of special structures and the wastewater nodes linking primary pipes without a wastewater structure.
See vw_swmm_junctions.sql
for details.
Outfalls
QGEP_SWMM creates an outfall for each QGEP discharge_point.
See vw_swmm_outfalls.sql
for details.
Dividers
QGEP_SWMM creates a divider for the manholes and special structures having the function
separating_structure
See
vw_swmm_dividers.sql
for details.
Storage Units
QGEP_SWMM creates a storage for some kind of QGEP infiltration installations and some kind of QGEP special structures.
See
vw_swmm_storages.sql
for details.
Conduits
QGEP_SWMM creates a conduit for each QGEP reach.
Roughness is created from
coefficient_of_friction
,wall_roughness
orswmm_default_coefficient_of_friction
(see: Coefficient of friction)QGEP profile type are matched to SWMM profile type, dimensions are computed from
reach.clear_height
andpipe_profile.height_width_ratio
Custom pipe profile described by a curve are currently not exported
See
vw_swmm_conduits.sql
andvw_swmm_xsections.sql
for details.
Pumps
QGEP_SWMM creates a pump for each QGEP pump. When a curve
qgep_od.hq_relation
is liked to the pump it is exported as a SWMM curve.See
vw_swmm_pumps.sql
andvs_swmm_curves.sql
for details.
Orifices
No correspondance in QGEP. Orifices are not created from QGEP objects. An empty table is created
See
vw_swmm_orifices.sql
for details.
Weirs
Are created from QGEP prank weir (without H/Q relation) and leaping weir.
See
vw_swmm_weirs.sql
for details.
Outlets
No correspondance in QGEP. However, outlets are created to export QGEP prank weir having a H/Q relation.
See
vw_swmm_outlets.sql
for details.
Transects
No correspondance in QGEP. This parameter must be set by the user in the template .inp
file or before running the simulation.
Copied from the template input file if exists.
Controls
No correspondance in QGEP. This parameter must be set by the user in the template .inp
file or before running the simulation.
Copied from the template input file if exists.
7.4.1.6. Quality
Land uses
QGEP_SWMM creates a SWMM land use kind for each QGEP planning zone kind.
See
vw_swmm_landuses.sql
Pollutants
No correspondance in QGEP. This parameter must be set by the user in the template .inp
file or before running the simulation.
Copied from the template input file if exists.
7.4.1.7. Curves
Are created for pumps linked to a
qgep_od.hq_relation
and for wastewater structures linked to aqgep_od.hydr_geom_relation
See
vw_swmm_curves.sql
for details.
7.4.1.8. Time series
No correspondance in QGEP. This parameter must be set by the user in the template .inp
file or before running the simulation.
Copied from the template input file if exists.
7.4.1.9. Time patterns
No correspondance in QGEP. This parameter must be set by the user in the template .inp
file or before running the simulation.
Copied from the template input file if exists.
7.4.1.10. Labels
No correspondance in QGEP. This parameter must be set by the user in the template .inp
file or before running the simulation.
Copied from the template input file if exists.
7.5. QGEP-SWMM data requirements
To run a sucessful simulation in SWMM the following minimal data has to be filled in to be matched to the swmm objects
SWMM attribute |
Description |
QGEP equivalent |
---|---|---|
Name |
User-assigned junction name. |
wastewater_node.obj_id |
X-Coordinate / Y-Coordinate |
Coordinate of node [COORDINATES] |
wastewater_node.situation_geometry |
Description |
Description of node |
wastewater_structure.identifier |
Tag |
Optional label used to categorize or classify the junction. |
manhole.obj_id |
Invert El. |
Invert elevation of the junction |
wastewater_node.bottom_level |
Max. Depth |
Maximum depth at the junction (i.e., the distance from the invert to the ground surface) (feet or meters). If zero, then the distance from the invert to the top of the highest connecting link will be used. |
Difference of cover.level minus wastewater_node.bottom_level |
SWMM attribute |
Description |
QGEP equivalent |
---|---|---|
Name |
User-assigned conduit name. |
wastewater_node.obj_id |
Inlet Node |
Name of node on the inlet end of the conduit (which is normally the end at higher elevation). |
from wastewater_node.obj_id |
Outlet Node |
Name of node on the outlet end of the conduit (which is normally the end at lower elevation). |
from wastewater_node.obj_id |
Description |
Description of conduit |
wastewater_networkelement.identifier |
Tag |
Optional label used to categorize or classify the conduit. |
wastewater_networkelement.fk_wastewater_structure |
Max. Depth |
Maximum depth of the conduit’s cross section |
Difference of Cover.level minus Wastewater_node.bottom_level |
Length |
Conduit length |
reach.length_effective or calculated from reach.progression_geometry if length_effective is empty |
Roughness |
Manning’s roughness coefficient. |
reach.wall_roughness |
InletOffset |
Depth or elevation of the conduit invert above the node invert at the inlet end of the conduit |
reach_point_from.level minus from_wastewater_node.bottom_level |
OutletOffset |
Depth or elevation of the conduit invert above the node invert at the outlet end of the conduit |
reach_point_to.level minus to_wastewater_node.bottom_level |
SWMM attribute |
Description |
QGEP equivalent |
---|---|---|
Shape |
geometric properties of the conduit’s cross section e.g. CIRCULAR. |
pipe_profile.profile_type |
Geom1 |
Maximum height of conduit |
reach.clear_height/1000 [m] to [mm] |
7.5.1. Coefficient of friction
The plugin will export the roughness according to these priorities:
If
reach.coefficient_of_friction
is set then it is converted (1/coefficient_of_friction
) and exported to SWMMElse if
reach.wall_roughness
andreach.clear_height
are set, it is converted ((1/(4 * SQRT(9.81)*POWER((32/re.clear_height/1000),(1/6))*LOG(((3.71*re.clear_height/1000)/(re.wall_roughness/1000)))))
) and exported.Else if
reach.swmm_default_coefficient_of_friction
is set then it is usedElse a default value of
0.01
is setSee
vw_swmm_conduites.sql
for details
Note
The formula to convert from Strickler to Coolebrook is documented in *ATV-DVWK STANDARD ATV-DVWK-A 110E, Hydraulic Dimensioning and Performance Verification of Sewers and Drains September 2001*
7.5.1.1. Populate default coefficient of friction
The table qgep_swmm.reach_coefficient_of_friction
contains default coefficient of Strickler for the reach materials.
The file ../project/qml/reach_coefficient_of_friction.qml
is the layer definition, that you can import in your QGIS project.
If the default values don’t match your needs you can edit them.
The function SWMM Set default coefficient of friction
will put in qgep_od.reach.swmm_default_coefficient_of_friction
these default values.
You can choose if you want to overwrite or not the values existing in this attribute.
Launch SWMM Set default coefficient of friction
:
Overwrite existing default values
: If checked the values stored inswmm_default_coefficient_of_friction
will be overwrited with new values.