7.8. Run SWMM Simulation
7.8.1. Run a simulation from SWMM interface
You can open the .inp file with SWMM and run the simulation from the interface.
7.8.2. Run a simulation with command line
{EXEPATH}\swmm5.exe {INPUTPATH}\{INPUTFILENAME}.inp {OUTPUTPATH}\{REPORTFILENAME}.rpt {OUTPUTPATH}\{OUTPUTFILENAME}.out
7.8.3. Run a simulation with QGEP-SWMM
The path to the SWMM executable must be set in the Processsing tools options. The plugin will launch the command line in the background.
Launch SWMM Execute:
INP file: the.inpfile generated during the previous stepRPT file: the output report file.rptcontaining the results (summary and full time serie)
7.8.4. Common running errors
The list of errors can be found here
ERROR 211: invalid number -XXX at line XXX of [JUNC] section:: A negative number is provided for the depth. Change the value in QGEP or in the.inpfile.